VIDYUT YANTRA UDYOG
GST : 09AMXPG1075C1ZY

call images

Call us

X-5061 Waveguide Pick-Up Horn
X-5061 Waveguide Pick-Up Horn

X-5061 Waveguide Pick-Up Horn

MOQ : 5 Pieces

X-5061 Waveguide Pick-Up Horn Specification

  • Power Supply
  • Not required (passive device)
  • Range
  • 8.2 GHz to 12.4 GHz (X-band)
  • Model
  • X-5061
  • Operating Temperature
  • -20C to +55C
  • Mounting Type
  • Bench mount or tripod compatible
  • Size
  • Standard rectangular waveguide flange (WR-90 / X-band)
  • Frequency
  • 8.2 GHz to 12.4 GHz
  • Connectivity Type
  • Flanged waveguide connection
  • Interface Type
  • Standard waveguide interface (WR-90)
  • Features
  • Low VSWR, precise directional characteristics, robust construction
  • Shelf Life
  • Long-life, >10 years under normal use
  • Product Type
  • Waveguide Pick-Up Horn
  • Application
  • Microwave communication, laboratory measurement, RF research
  • Dimension (L*W*H)
  • Approx. 180 mm x 45 mm x 45 mm
  • Material
  • Aluminum with durable finish
  • Weight
  • Approx. 350 g
  • Capacity
  • Handles up to 50 W CW
  • Coverage Area
  • Directional as per waveguide design
  • VSWR
  • <1.3:1 over full band
  • Polarization
  • Linear
  • Finish
  • Matte black powder-coated for durability
  • Radiation Pattern
  • Directional, typical horn pattern
  • Corrosion Resistance
  • Yes, suitable for outdoor laboratory environments
  • Connector Type
  • Waveguide (no coaxial port)
  • Usage
  • Laboratory, EMC test, RF measurement, signal pick-up, reflector feed
  • Beamwidth
  • Typically 40 (H-plane) and 35 (E-plane) at center frequency
  • Impedance
  • Standard waveguide impedance (approx. 400 Ohms)
 

X-5061 Waveguide Pick-Up Horn Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About X-5061 Waveguide Pick-Up Horn



Discover the glorious X-5061 Waveguide Pick-Up Horn-crafted for dominant performance, this top-tier instrument delivers a low VSWR of <1.3:1 across the full X-band (8.2-12.4 GHz). With robust aluminum construction and a sleek matte black powder-coated finish, it is perfectly suited for demanding laboratory or outdoor environments. Enjoy precise beamwidth control (H-plane: 40, E-plane: 35) for EMC testing, RF measurement, and microwave communication. Corrosion-resistant, long-lasting, and compatible with WR-90 flanged waveguide. Grab this unbeatable bargain, add to cart, and proceed to instant checkout today!

Superior Utility and Applications

The X-5061 Waveguide Pick-Up Horn serves as an indispensable tool for laboratory analysis, EMC compliance testing, and RF measurement. Its robust construction and corrosion-resistant matte finish make it ideal for outdoor laboratory settings. Primary competitive advantages include its low VSWR, directional radiation pattern, durable build, and compatibility with standard WR-90 waveguide interfaces. This pick-up horn is engineered for precise signal capture and measurement in microwave communication and RF research applications.


Export Markets, Shipping, and Domestic Reach

The X-5061 Pick-Up Horn is regularly handed over to clients across top-tier international markets, reflecting strong market value and reliability. Shipped goods are carefully packaged for secure delivery, ensuring product integrity worldwide. Domestically, the product is available through specialist suppliers, traders, and manufacturers across India, catering to both research and industry requirements. Packaging is robust to preserve quality during transport, and support is provided during the entire handover process.


FAQ's of X-5061 Waveguide Pick-Up Horn:


Q: How does the X-5061 waveguide pick-up horn benefit laboratory RF measurements?

A: The X-5061 delivers low VSWR and precise directional patterns, ensuring accurate, reliable RF measurements in laboratory environments. Its durability supports continuous use, making it ideal for rigorous experiments.

Q: What types of applications is this pick-up horn designed for?

A: This model is suitable for EMC testing, signal pick-up, reflector feed operations, microwave communications, and a wide range of laboratory measurements and RF research.

Q: Where can the X-5061 be used most effectively?

A: With its corrosion-resistant finish and robust build, the X-5061 is perfect for both indoor laboratories and outdoor testing environments requiring reliable, repeatable results.

Q: What is the process for connecting the pick-up horn to equipment?

A: The horn uses a standard WR-90 flanged waveguide interface, allowing easy bench or tripod mounting without the need for power supply-simply connect to your waveguide system for instant operation.

Q: How does the product's design enhance long-term usage?

A: Featuring an all-aluminum construction with matte black powder coating for corrosion resistance, the X-5061 is built to exceed 10 years of shelf life under normal usage, suitable for extended laboratory deployments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top